Remote Control Commands
R&S
®
SMBV100B
822User Manual 1178.4460.02 ─ 03
// ******************************************************************
// If the attenuation between the interconnection LO OUT and LO IN is
// greater than 1 dB at the oscillator frequency,
// we recommend that you perform the LO level adjustment
// ******************************************************************
:CALibration:LOSCillator:Coupling:LOCAL?
// ******************************************************************
// Address and reset the third instrument
// ******************************************************************
*RST; *CLS
// ******************************************************************
// Configure the oscillator signal of the third next instrument
// ******************************************************************
SOURce:FREQuency 5 GHz
SOURce:FREQuency:LOSCillator:MODe EXTernal
SOURce:FREQuency:LOSCillator:OUTPut:STATe OFF
See also:
"To configure LO coupling with cascaded instruments to achieve phase coherence"
on page 308
[:SOURce<hw>]:FREQuency:LOSCillator:INPut:FREQuency?........................................... 822
[:SOURce<hw>]:FREQuency:LOSCillator:MODE.............................................................. 823
[:SOURce<hw>]:FREQuency:LOSCillator:OUTPut:FREQuency?........................................823
[:SOURce<hw>]:FREQuency:LOSCillator:OUTPut:STATe.................................................. 823
[:SOURce<hw>]:FREQuency:MODE................................................................................824
[:SOURce<hw>]:FREQuency[:CW|FIXed].........................................................................824
[:SOURce<hw>]:FREQuency[:CW|FIXed]:RCL................................................................. 825
[:SOURce<hw>]:FREQuency:MANual..............................................................................825
[:SOURce<hw>]:FREQuency:MULTiplier.......................................................................... 826
[:SOURce<hw>]:FREQuency:OFFSet.............................................................................. 826
[:SOURce<hw>]:FREQuency:CENTer.............................................................................. 827
[:SOURce<hw>]:FREQuency:SPAN.................................................................................827
[:SOURce<hw>]:FREQuency:STARt................................................................................ 827
[:SOURce<hw>]:FREQuency:STOP.................................................................................828
[:SOURce<hw>]:FREQuency:STEP:MODE...................................................................... 828
[:SOURce<hw>]:FREQuency:STEP[:INCRement]............................................................. 828
[:SOURce<hw>]:FREQuency:LOSCillator:INPut:FREQuency?
Queries the required external reference frequency.
Return values:
<Frequency> float
Range: 100E3 to 20E9
Increment: 0.01
*RST: 0
Example: See Example "Set up of LO coupling and LO level adjustment
with three Rohde & Schwarz signal generators" on page 821.