20 - 172
20PROFINET COMMUNICATION
(5) SI unit position (P24744)
The SI position unit is returned.
SI unit position (P24744) is set automatically with the control mode, [Pr. PT01] and [Pr. PT03].
In the indexer method, "00000000h" is returned.
PNU
Sub
Access
Name
Data Type
Description
Default
24744
0
R/W
SI unit position
Unsigned32
SI position unit
0
PNU
Sub
Range
Units
EEP-ROM
Parameter
24744
0
Refer to the following table.
pos units
Impossible
-
[Pr. PT01] setting
[Pr. PT03] setting
Value
_ 0 _ _ (mm)
0 (× 1)
FA010000h (0.001 mm)
1 (× 10)
FB010000h (0.01 mm)
2 (× 100)
FC010000h (0.1 mm)
3 (× 1000)
FD010000h (1 mm)
_ 1 _ _ (inch)
0 (× 1)
FCC00000h (0.0001 inch)
1 (× 10)
FDC00000h (0.001 inch)
2 (× 100)
FEC00000h (0.01 inch)
3 (× 1000)
FFC00000h (0.1 inch)
_ 2 _ _ (degree)
FD410000h (0.001 degree)
_ 3 _ _ (pulse)
00000000h (1 pulse)
(6) SI unit velocity (P24745)
The SI unit velocity is returned.
PNU
Sub
Access
Name
Data Type
Description
Default
24745
0
R/W
SI unit velocity
Unsigned32
SI unit velocity
0
PNU
Sub
Range
Units
EEP-ROM
Parameter
24745
0
FB010300h (0.01 mm/s),
FEB44700h (0.01 r/min)
vel units
Impossible