APPENDIX
App. - 23
Series
LEFB25
LEFB25U
LEFB32
LEFB32U
LEFB40
LEFB40U
Lead symbol
S
Lead
54
Parameter *1,*2
Para
No
Initial
value
Recommended value
Electronic gear numerator *3.
PA06
1
4194304
Electronic gear denominator *3.
PA07
1
54000
Command mode selection *3
PT01
0300
0000
Feel length multiplication (STM)
(Multiplier)
PT03
0000
0000 (<1000 stroke)/0001 (>1000 stroke)
Home position return method
PT45
37
-36 (Home position return direction: Motor side, Stopper type)
Home position return Speed (rpm)
PT05
100
33
Stopper type home position return
stopper time (msec)
PT10
100
200
Stopper type home position return torque
limit value (%)
PT11
15
24
Home position return acceleration
time constant (msec)
PT56
0
2700
Regenerative option
PA02
0000
0000 (Non)/0002 (LEC-MR-RB-032)
Rotation direction selection
PA14
0
1 (+
Counter
motors
side)
0 (+
Counter
motors
side)
1 (+
Counter
motors
side)
0 (+
Counter
motors
side)
1 (+
Counter
motors
side)
0 (+
Counter
motors side)
Load to motor inertia moment ratio
PB06
7
50
Function selection E-3
PE41
0000
0001(Robust filter enabled)
Parameter setting required.
Differs to initial value
*1. Parameter is set to the recommended value. Please set parameter according to customer application.
*2. Mechanical resonance may occur depending on the shape or mounting orientation of the work piece.
Please change this parameter during initial configuration.
(Parameter initial configuration Set the recommended parameter value Operation start)
*3. Minimum actuator travel distance of 1[μm].
CAUTION
When the stopper type home position return is used and the actuator end is set to
the home position, please pay attention to the actuator movable range when
commanding the position to prevent collision with both ends of the actuator due to
overshoot.
When the origin (0 mm) is set at the actuator end, the movable range of this
actuator is from [+3mm] to [actuator stroke +3mm].

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals