5. PARAMETERS
5 - 88
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT
EIP
PNT
PT49
STA
Acceleration
time constant
Set an acceleration time taken from 0 r/min or 0 mm/s to the rated speed for the
command. When a value exceeding 2000 ms is set in other than the profile velocity
mode (pv), [AL. F4] will occur and the servo motor cannot be driven.
Profile mode
Set the acceleration time constant in the position mode and
the velocity mode.
Point table method
Set the acceleration time constant in the Jog mode (jg).
Indexer method
Set the acceleration time constant in the indexer mode (idx)
and Jog mode (jg).
If the preset speed command is lower
than the rated speed, acceleration/
deceleration time will be shorter.
Time
[Pr. PT50] setting
0 r/min
Rated
speed
Servo motor speed
[Pr. PT49] setting
(0 mm/s)
For example, for the servo motor with the rated speed of 3000 r/min, set 3000 (3 s)
to increase speed from 0 r/min to 1000 r/min in 1 s.
This parameter corresponds to "Profile acceleration (PNU: 24707, Sub: 0)". When
this parameter is mapped for the Process Data communication, the value written
with Setup software (MR Configurator2
TM
) is overwritten with the upper side. Thus,
do not write a value with Setup software (MR Configurator2
TM
).
Setting range: 0 to 50000
0