6. NORMAL GAIN ADJUSTMENT
6 - 10
(5) If an alarm occurs
If an alarm occurs during tuning, one-touch tuning will be forcibly terminated.
Remove the cause of the alarm and execute one-touch tuning again.
(6) If a warning occurs
If a warning which continue the motor driving occurs during the tuning, one-touch tuning will be
continued.
If a warning which does not continue the motor driving occurs during the tuning, one-touch tuning will
be stopped.
(7) Initializing one-touch tuning
You can clear the parameter values set with one-touch tuning.
Refer to table 6.1 for the parameters which you can clear.
Clicking "Return to value before adjustment" in the one-touch tuning window of setup software (MR
Configurator2
TM
) enables to return the parameter to the value before clicking "start".
In addition, pushing "Return to initial value" in the one-touch tuning window enables to rewrite the
parameter to the initial value.
When the initialization of one-touch tuning is completed, the following window will be displayed.
(returning to initial value)