8. TROUBLESHOOTING
8 - 10
Network communication
error
Network communication error 1
Network communication error 2
Network communication error 3
USB communication
time-out error/
serial communication
time-out error/
Modbus RTU
communication time-out
error
USB communication time-out
error/serial communication time-out
error
Modbus RTU communication time-out
error
CC-Link IE
communication error
CC-Link IE communication error 1
CC-Link IE communication error 2
Master station setting error 1
Master station setting error 2
CC-Link IE communication error 3
CC-Link IE communication error 4
CC-Link IE communication error 5
USB communication
error/
serial communication
error/
Modbus RTU
communication error
USB communication receive error/serial
communication receive error
USB communication checksum error/
serial communication checksum error
USB communication character error/
serial communication character error
USB communication command error/
serial communication command error
USB communication data number
error/serial communication data number
error
Modbus RTU communication receive
error
Modbus RTU communication message
frame error
Modbus RTU communication CRC error
After resolving the source of trouble, cool the equipment for approximately 30 minutes.
The following shows three stop methods of DB, EDB, and SD.
DB: Stops with dynamic brake. (Coasts for the driver without dynamic brake.)
[AL. 30.1], [AL. 32.2], [AL. 32.4], [AL. 51.1], [AL. 51.2], [AL. 888]
EDB: Electronic dynamic brake stop (available with specified servo motors)
Refer to the following table for the specified servo motors. The stop method for other than the
specified servo motors will be DB.
LE-T5-
□
, LE-T6-
□
, LE-T7-
□
, LE-T8-
□
SD: Forced stop deceleration
This is applicable when [Pr. PA04] is set to the initial value. The stop system of SD can be changed to
DB using [Pr. PA04].
In some upper side communication status, the alarm factor may not be removed.
This alarm will occur only in the J3 compatibility mode.
Reset this while all the safety observation functions are stopped.