11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 19
(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent.
Table 11.3 Wires for option cables
Type
Model
Length
[m]
Core size
[mm
2
]
Number
of Cores
Characteristics of one core
(Note 2)
Finishing
OD [mm]
Wire model
Structure
[Wires/mm]
Conductor
resistance
[ /km]
Insulation
coating OD
d [mm]
(Note 1)
Encoder
Cable
LE-CSE-SA
2 to 10
AWG22
6
(3 pairs)
7/0.26
53
or less
1.2
7.1 0.3
(Note 3)
VSVP 7/0.26 (AWG#22 or
equivalent)-3P
Ban-gi-shi-16823
LE-CSE-SB
LE-CSE-RA
2 to 10
AWG22
6
(3 pairs)
70/0.08
56
or less
1.2
7.1 0.3
(Note 3)
ETFE SVP 70/0.08 (AWG#22 or
equivalent)-3P Ban-gi-shi-16824
LE-CSE-RB
Motor cable
LE-CSM-SA
2 to 10
AWG18
4
34/0.18
21.8
or less
1.71
6.2 0.3
HRZFEV-A(CL3) AWG18 4 cores
LE-CSM-SB
2 to 10
LE-CSM-RA
2 to 10
(Note 5)
AWG19
4
150/0.08
29.1
or less
1.63
5.7 0.5
(Note 4)
RMFES-A(CL3X) AWG19 4 cores
LE-CSM-RB
2 to 10
Lock cable
LE-CSB-SA
2 to 10
AWG20
2
21/0.18
34.6
or less
1.35
4.7 0.1
HRZFEV-A(CL3) AWG20 2 cores
LE-CSB-SB
2 to 10
LE-CSB-RA
2 to 10
Note 5)
AWG20
2
110/0.08
39.0
or less
1.37
4.5 0.3
(Note 4)
RMFES-A(CL3X) AWG20 2 cores
LE-CSB-RB
2 to 10
Note 1. d is as shown below.
d
Conductor
Insulation sheath
2. Standard OD. Max. OD is about 10% greater.
3. Purchased from Toa Electric Industry
4. Purchased from taisei
5. These wire sizes assume that the UL-compliant wires are used at the wiring length of 10m.

Table of Contents