18 - 143
18EtherCAT COMMUNICATION
(5) SM input parameter (1C33h)
Index
Sub
Name
Data Type
Access
PDO Mapping
1C33h
0
SM input parameter
UNSIGNED8
ro
Impossible
1
Synchronization Type
UNSIGNED16
rw
2
Cycle Time
UNSIGNED32
3
Shift Time
rw (Note)
4
Synchronization Types supported
UNSIGNED16
ro
5
Minimum Cycle Time
UNSIGNED32
6
Calc and Copy Time
9
Delay Time
12
Cycle Time Too Small
UNSIGNED16
Index
Sub
Default
Range
Units
EEP-ROM
Parameter
1C33h
0
12
0Ch (12)
Impossible
1
0
0000h or 0002h
2
250000
0003D090h (250000)
0007A120h (500000)
000F4240h (1000000)
001E8480h (2000000)
ns
3
27778
00000000h to FFFFFFFFh
4
0025h
0025h (35)
5
250000
0003D090h (250000)
ns
6
306055
00000000h to FFFFFFFFh
9
0
00000000h
12
0
0000h
Note.
No value can be written because Shift time (1C33: 3) is set automatically. Writing any value causes SDO Abort Code (0609
0030h Value range of parameter exceeded).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals