20.PROFINET COMMUNICATION
(4) Current alarm (P10817)
The number of the current alarm is returned. When no alarm has occurred, "00000000h" is returned. The
description of the values is as follows. If [AL. 16.3] occurs, "00160003h" is returned.
Current alarm
Bit 0 to Bit 15: Alarm detail number
Bit 16 to Bit 31: Alarm number
(5) Parameter error number (P10820)
When [AL. 37 Parameter error] has occurred, the number of the parameters which cause the error is
returned. Refer to Parameter error list (P10821) for the number of each parameter which causes the
error.
(6) Parameter error list (P10821)
When [AL. 37 Parameter error] has occurred, the number of the parameter which causes the error is
returned. For forms of parameter error Nos., refer to chapter 8.13. If [Pr. PC01] is an error factor, "0201h"
is returned.
If more than 17 parameter errors have occurred, the 17th and later parameter errors are returned after
the parameters are corrected and the power is cycled.