20 - 142
20PROFINET COMMUNICATION
(62) Alarm Monitor 48 Command position (P11184)
The command position at alarm occurrence is returned. In the indexer method, the value is fixed to "0".
PNU
Sub
Access
Name
Data Type
Description
Default
11184
0
R
Alarm Monitor 48
Command position
Integer32
Command position at alarm occurrence
PNU
Sub
Range
Units
EEP-ROM
Parameter
11184
0
80000000h to 7FFFFFFFh
pos units
Impossible
(63) Alarm Monitor 49 Command remaining distance (P11185)
The command remaining distance at alarm occurrence is returned.
PNU
Sub
Access
Name
Data Type
Description
Default
11185
0
R
Alarm Monitor 49
Command remaining
distance
Integer32
Command remaining distance at alarm
occurrence
PNU
Sub
Range
Units
EEP-ROM
Parameter
11185
0
80000000h to 7FFFFFFFh
pos units
Impossible
(64) Alarm Monitor 50 Point table No./Program No./Station position No.. (P11186)
Point table No. or station position No. at alarm occurrence is returned.
PNU
Sub
Access
Name
Data Type
Description
Default
11186
0
R
Alarm Monitor 50 Point
table No./Program
No./Station position No..
Integer16
Point table No./station position No. at
alarm occurrence
PNU
Sub
Range
Units
EEP-ROM
Parameter
11186
0
00000000h to 000000FFh
Impossible