Phaser 4500/4510 Service Manual 3-55
Error Messages and Codes
2 Check feeder harness 5 of the tray 3
feeder:
1.Remove Optional 550-Sheet Paper
Feeder.
2.Disconnect P/J84 from the 550-
sheet feeder PWBA.
3.Check the following for continuity:
J84-1 <=> J8483-10
J84-2 <=> J8483-9
J84-3 <=> J8483-8
J84-4 <=> J8483-7
J84-5 <=> J8483-6
Is each continuous?
Go to step 3. Replace feeder
harness 5.
3 Check feeder harness 2 of the tray 4
feeder:
1.Remove the Optional 550-Sheet
Paper Feeder.
2.Disconnect P/J8483.
3.Check the following for continuity:
J8483-1 <=> J83-10
J8483-2 <=> J83-9
J8483-3 <=> J83-8
J8483-4 <=> J83-7
J8483-5 <=> J83-6
Is each continuous?
Go to “Optional
550-Sheet
Feeder PWBA
(Tray 4)” on
page 4-40.
Replace feeder
harness 2.
Troubleshooting Procedure (continued)
Steps Actions and Questions Yes No