8-110 Phaser 4500/4510 Service Manual
FRU Disassembly
6. Remove the motor bracket together with the duplex unit motor and duplex
unit switch.
Note
When removing the motor bracket, be careful not to lose the gears
attached to the duplex unit housing cover.
7. Remove the two 6 mm screws that attach the duplex unit motor to the
motor bracket.
8. Remove the duplex unit motor.
Duplex Unit Switch
(PL21.1.27)
Procedure:
1. Remove the duplex unit motor bracket as described in the duplex unit
motor procedure (page 8-109).
2. Disconnect the connector of the duplex unit cover assembly harness from
the connector (P/J52) of the duplex unit switch.
3. Release the hooks of the duplex unit switch, and remove it from the motor
bracket.
1.Duplex unit cover harness 4.Motor bracket
2.Duplex unit switch 5.Latch spring
3.Duplex unit ground wire 6.Duplex unit housing cover
s4510-196
4
6
5
3
1
2