Phaser 4500/4510 Service Manual 8-109
FRU Disassembly
Duplex Unit Motor
(PL21.1.29)
Procedure:
1. Remove the left cover (page 8-96).
2. Remove the 6 mm screw that attaches the duplex unit assembly harness
ground
3. Remove the three 8 mm tapping screws that attach the motor bracket to
the duplex unit housing cover.
4. Remove the screw that mounts the duplex unit PWBA to the motor
bracket.
5. Remove the latch spring.
1.Duplex unit motor 4.Latch spring
2.Ground wire 5.Duplex unit housing cover
3.Motor bracket
3
5
4
2
1
s4510-195