8-114 Phaser 4500/4510 Service Manual
FRU Disassembly
10. Lift the stacker cover with the attached stacker tray assembly to remove it
from the stacker.
Replacement:
Caution
To avoid breaking the sensor flag off the right end of the stack full
actuator, be very careful while sliding the stacker assembly back into the
stacker cover. It is important that the flag shaft clears the output tray hinge
bracket.
1. Lay the stacker cover on its back side.
2. Rotate the stacker tray up until it contacts the top of the stacker cover.
3. Slide the stacker up into place inside the stacker cover, being careful to
not break the output full actuator arm or flag.
4. Install the four 8 mm tapping screws that attach the stacker cover to the
stacker.
1.Stacker cover
s4500-201
1