Appendix E: Medical Usage Notices
XirrusXR‐1000/2000/4000/6000Serieswirelessdeviceshavebeentestedand
foundtocomplywiththerequirementsofIEC60601‐1‐2.
Section5.2.1.1‐TheXirruswirelessdeviceneedsspecialprecautionsregarding
EMCandmustbeinstalledandputintoserviceaccordingtotheEMC
informationprovidedinthisUser’sGuideand
intheQuickInstallationGuidefor
theXirrusAPorAP.
PortableandmobileRFcommunicationsequipmentcanaffectMedicalElectrical
Equipment.
Section 5.2.2.1 (c)
Table1
Section5.2.2.1(d)–TheXirruswirelessdeviceshouldnotbeusedadjacenttoor
stackedwithotherequipment.Ifadjacentorstackeduseisnecessary,
the
equipmentshouldbeobservedtoverifynormaloperationintheconfigurationin
whichitwillbeused.
Guidance and manufacturer’s declaration – electromagnetic emissions
The Xirrus wireless device is intended for use in the electromagnetic environment specified below.
The customer or the user of the Xirrus device should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
RF emissions CISPR 11 Group 1 The Xirrus wireless device uses RF energy only for
its internal function. Therefore, its RF emissions are
very low and are not likely to cause any interference
in nearby electronic equipment.
RF emissions CISPR 11 Class A Xirrus wireless devices are suitable for use in all
establishments other than domestic and those
directly connected to the public low-voltage power
supply network that supplies buildings used for
domestic purposes.
Harmonic emissions IEC
61000-3-2
Not
Applicable
Voltage fluctuations/flicker
emissions IEC 61000-3-3
Not
Applicable