EasyManua.ls Logo

ABB AC500 V3 - 1.4.4 EtherCAT; 1.4.4.1 CM579-ETHCAT - EtherCAT master; 1.4.4.1.1 Intended purpose; 1.4.4.1.2 Connections

ABB AC500 V3
1029 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.4.4 EtherCAT
1.4.4.1 CM579-ETHCAT - EtherCAT master
1 5 LEDs for state display
2 2 rotary switches for address setting (not used)
3 Label
4 2 communication interfaces RJ45 (ETHCAT1 and ETHCAT2)
1.4.4.1.1 Intended purpose
Communication module CM579-ETHCAT is for EtherCAT communication.
The comunication module is configured via the dual-port memory by means of a system config-
urator. The configuration is saved on a non-volatile Flash EPROM memory.
1.4.4.1.2 Connections
Field bus interfaces
The EtherCAT communication module provides 2 RJ45 interfaces with the following pin assign-
ment. The pin assignment is used for the EtherCAT slaves (communication interface modules
CI5xy-ETHCAT) as well.
Device specifications
Communication modules (AC500 standard) > EtherCAT
2022/01/313ADR010278, 3, en_US112