Accuracy of thermocouple ranges at 25 °C (with cold junction compensation)
Thermocouple Type Range Accuracy
E -270 °C...-220 °C
-220 °C...+1000 °C
±2 %
±0.6 %
J -210 °C...+1200 °C ±0.6 %
K -270 °C...-220 °C
-220 °C...+1372 °C
±1.5 %
±0.6 %
N -270 °C...-150 °C
-150 °C...+1300 °C
±2 %
±0.6 %
R -50 °C...+150 °C
+150 °C...+1768 °C
±1.5 %
±0.6 %
S -50 °C...+150 °C
+150 °C...+1768 °C
±1.5 %
±0.6 %
T -270 °C...-240 °C
-240 °C...-0 °C
0 °C...+400 °C
±3 %
±2 %
±0.6 %
These accuracy values are valid only for stable module temperatures.
Ordering data
Part no. Description Product life cycle phase *)
1TNE 968 902 R1103 AI563, analog input module, 4 AI,
thermocouple
Active
1TNE 968 901 R3101 Terminal block TA563-9, 9 pins, screw
front, cable side, 6 pieces per unit
Active
1TNE 968 901 R3102 Terminal block TA563-11, 11 pins,
screw front, cable side, 6 pieces per
unit
Active
1TNE 968 901 R3103 Terminal block TA564-9, 9 pins, screw
front, cable front, 6 pieces per unit
Active
1TNE 968 901 R3104 Terminal block TA564-11, 11 pins,
screw front, cable front, 6 pieces per
unit
Active
1TNE 968 901 R3105 Terminal block TA565-9, 9 pins, spring
front, cable front, 6 pieces per unit
Active
1TNE 968 901 R3106 Terminal block TA565-11, 11 pins,
spring front, cable front, 6 pieces per
unit
Active