35. RECIPE
It reads and writes several PLC devices and read or write operation are operated by read or write
trigger.
It is able to transmit large volumes of data to device collectively through recipe function using write
operation and save large volumes of PLC inner device value to recipe memory of GP using read
operation.
35.1 CONFIGURATION IN EDITOR
(1) Designate device of “System signal1” in system information window and “Current recipe number
in check box.
(2) Write each recipe file : It is able to write 256 recipe files from 1 to 256. The name of recipe file is
configured maximum 32 of ASCII character, GP recognizes recipe file number, not a recipe file
name, user can designate name as convenient to divide.
(3) Designation of read/write trigger device : It is able to designate read/write trigger separately.
Recipe read function is not used, read trigger is not required to designate while write trigger
should be designated.
(4) Designation of read/write trigger condition : It is able to designate as ON, OFF. When it is
designated as ON, trigger is occurred in rising edge of trigger device and it is occurred in falling
edge when it is designated as OFF.
(5) Designation of save device : It is able to configure only with 16bit word device and designate as
maximum 4000 for a recipe. Configuration of device point and read/write trigger for recipe files
excluding the first recipe is fixed as the value configured in the first file and devic and device
data type and the initial value of device are only can be configured differently.
35.2 OPERATION PROCEDURE IN MAIN DEVICE
(1) Read read/write device of PLC.
(2) Confirm read/write trigger.
(3) Read recipe device when read/write trigger is occurred, execute read/write operation for the
appropriate file with recipe file number.
Recipe read operation : Read all PLC devices registered in recipe file and adjust recipe file to
recipe device value change into current value of the device.
Recipe write operation: Configure all PLC devices registered in recipe file as designated value in
recipe.