Interfaces WideArea Networks(WANs)
IX20 User Guide
103
(config network interface my_wan surelink actions 0)> custom_
action_commands_modem "string"
(config network interface my_wan surelink actions 0)>
l
Set the time to wait before the next test is run. If set to the default value of 0s,
the test interval is used.
(config network interface my_wan surelink actions 0)>
override_interval int
(config network interface my_wan surelink actions 0)>
f. Repeat for each additional recovery action.
7. Optional SureLink configuration parameters:
a. Type ... to return to the root of the configuration:
(config network interface my_wan surelink actions 0)> ...
(config)>
b. Set the test interval between connectivity tests:
(config)> network interface my_wan surelink interval value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set interval to ten minutes, enter either 10m or 600s:
(config)> network interface my_wan surelink interval 600s
(config)>
The default is 15m.
c. If more than one test target is configured, set the success condition:
(config)> network interface my_wan surelink success_condition value
(config)>
where value is either:
n
one: Only one test needs to pass for Surelink to consider an interface to be up.
n
all: All tests need to pass for SureLink to consider the interface to beup.
d. Set the number of times that the test must pass after failure, before the interface is
determined to beworking and is reinstated.
(config)> network interface my_wan surelink pass_threshold int
(config)>
The default is 1.
e. Set the amount of time that the device should wait for a response to a test attempt before
considering it to have failed: