Monitoring ConfigureNetFlow Probe
IX20 User Guide
1066
9. Add collectors:
a. Add a collector:
(config)> add monitoring netflow collector end
(config monitoring netflow collector 0)>
b. Set the IPaddress of the collector:
(config monitoring netflow collector 0)> address ip_address
(config monitoring netflow collector 0)>
c. (Optional) Set the port used by the collector:
(config monitoring netflow collector 0)> port port
(config monitoring netflow collector 0)>
d. (Optional) Set a label for the collector:
(config monitoring netflow collector 0)> label "This is a collector."
(config monitoring netflow collector 0)>
Repeat to add additional collectors.
10. Save the configuration and apply the change
(config monitoring netflow collector 0)> save
Configuration saved.
>
11. Typeexit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.