1107
Views
System view
Predefined user roles
network-admin
Parameters
limit-value: Specifies the limit in the range of 2 to 1024.
Usage guidelines
If unresolvable packets received from an IP address within 5 seconds exceed the limit, the device
stops processing the packets from that IP address until the 5 seconds elapse.
Examples
# Configure the device to process a maximum of 100 unresolvable packets per source IP address
within 5 seconds.
<Sysname> system-view
[Sysname] arp source-suppression limit 100
Related commands
display arp source-suppression
display arp source-suppression
Use display arp source-suppression to display information about the current ARP source
suppression configuration.
Syntax
display arp source-suppression
Views
Any view
Predefined user roles
network-admin
network-operator
Examples
# Display information about the current ARP source suppression configuration.
<Sysname> display arp source-suppression
ARP source suppression is enabled
Current suppression limit: 100
Table 173 Command output
Field
Description
Current suppression limit
Maximum number of unresolvable packets that can be processed per
source IP address within 5 seconds.

Table of Contents

Other manuals for H3C MSR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C MSR Series and is the answer not in the manual?

H3C MSR Series Specifications

General IconGeneral
CategoryNetwork Router
IPv6 SupportYes
DimensionsVaries by model
WeightVaries by model
Product TypeModular Router
PortsVaries by model
WAN InterfacesVaries by model
FirewallYes
QoSYes
Wireless SupportVaries by model
USB PortsVaries by model
Console PortYes
Power SupplyVaries by model
RedundancyVaries by model
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity5% to 95% non-condensing
SeriesMSR
CertificationsCE, FCC, RoHS

Related product manuals