677
Usage guidelines
If an SFTP connection is idle when the idle timeout timer expires, the system automatically
terminates the connection. To promptly release connection resources, set the idle timeout timer to a
small value when many SFTP connections concurrently exist.
Examples
# Set the idle timeout timer to 500 minutes for SFTP connections.
<Sysname> system-view
[Sysname] sftp server idle-timeout 500
Related commands
display ssh server
ssh ip alias
Use ssh ip alias to associate an SSH redirect listening port with an IP address.
Use undo ssh ip alias to delete the IP address associated with the SSH redirect listening port.
Syntax
ssh ip alias ip-address port-number
undo ssh ip alias ip-address
Default
An SSH redirect listening port is not associated with an IP address.
Views
System view
Predefined user roles
network-admin
Parameters
ip-address: Specifies the IP address to be associated with the SSH redirect listening port. The IP
address cannot be the address of an interface on the device, but it can be on the same subnet as an
interface IP address on the device.
port-number: Specifies an SSH redirect listening port number in the range of 4000 to 50000.
Usage guidelines
The following matrix shows the command and hardware compatibility:
MSR810/810-W/810-W-DB/810-LM/810-W-LM/810-10-PoE
/810-LM-HK/810-W-LM-HK/810-LMS/810-LUS
No
MSR2600-10-X1 Yes
MSR 2630 Yes
MSR3600-28/3600-51 Yes
MSR3600-28-SI/3600-51-SI Yes
MSR3610-X1/3610-X1-DP/3610-X1-DC/3610-X1-DP-DC Yes
MSR 3610/3620/3620-DP/3640/3660 Yes
MSR5620/5660/5680 No