Related commands
accounting default
hwtacacs scheme
local-user
radius scheme
accounting portal
Use accounting portal to specify accounting methods for portal users.
Use undo accounting portal to restore the default.
Syntax
In non-FIPS mode:
accounting portal { broadcast radius-scheme radius-scheme-name1 radius-scheme
radius-scheme-name2 [ local ] [ none ] | local [ none ] | none | radius-scheme
radius-scheme-name [ local ] [ none ] }
undo accounting portal
In FIPS mode:
accounting portal { broadcast radius-scheme radius-scheme-name1 radius-scheme
radius-scheme-name2 [ local ] | local | radius-scheme radius-scheme-name [ local ] }
undo accounting portal
Default
The default accounting methods of the ISP domain are used for portal users.
Views
ISP domain view
Predefined user roles
network-admin
Parameters
broadcast: Broadcasts accounting requests to servers in RADIUS schemes.
radius-scheme radius-scheme-name1: Specifies the primary broadcast RADIUS scheme by its
name, a case-insensitive string of 1 to 32 characters.
radius-scheme radius-scheme-name2: Specifies the backup broadcast RADIUS scheme by its
name, a case-insensitive string of 1 to 32 characters.
local: Performs local accounting.
none: Does not perform accounting.
radius-scheme radius-scheme-name: Specifies a RADIUS scheme by its name, a case-insensitive
string of 1 to 32 characters.
Usage guidelines
You can specify one primary accounting method and multiple backup accounting methods.
When the primary method is invalid, the device attempts to use the backup methods in sequence.
For example, the accounting portal radius-scheme radius-scheme-name local none command
specifies a primary default RADIUS accounting method and two backup methods (local accounting
and no accounting). The device performs RADIUS accounting by default and performs local

Table of Contents

Other manuals for H3C MSR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C MSR Series and is the answer not in the manual?

H3C MSR Series Specifications

General IconGeneral
CategoryNetwork Router
IPv6 SupportYes
DimensionsVaries by model
WeightVaries by model
Product TypeModular Router
PortsVaries by model
WAN InterfacesVaries by model
FirewallYes
QoSYes
Wireless SupportVaries by model
USB PortsVaries by model
Console PortYes
Power SupplyVaries by model
RedundancyVaries by model
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity5% to 95% non-condensing
SeriesMSR
CertificationsCE, FCC, RoHS

Related product manuals