Examples
# Enable SSH redirect on TTY line 7.
<Sysname> system-view
[Sysname] line tty 7
[Sysname-line-tty7] ssh redirect enable
Related commands
ssh redirect listen-port
ssh redirect disconnect
ssh redirect listen-port
Use ssh redirect listen-port to set a listening port of SSH redirect.
Use undo ssh redirect listen-port to restore the default.
Syntax
ssh redirect listen-port port-number
undo ssh redirect listen-port
Default
The SSH redirect listening port number is the absolute user line number plus 4000.
Views
AUX line view
TTY line view
Predefined user roles
network-admin
Parameters
port-number: Specifies the number of the SSH redirect listening port, in the range of 4000 to 50000.
Usage guidelines
The following matrix shows the command and hardware compatibility:
Hardware
Command compatibility
MSR810/810-W/810-W-DB/810-LM/810-W-LM/810-10-PoE
/810-LM-HK/810-W-LM-HK/810-LMS/810-LUS
No
MSR2600-10-X1 Yes
MSR 2630 Yes
MSR3600-28/3600-51 Yes
MSR3600-28-SI/3600-51-SI Yes
MSR3610-X1/3610-X1-DP/3610-X1-DC/3610-X1-DP-DC Yes
MSR 3610/3620/3620-DP/3640/3660 Yes
MSR5620/5660/5680 No
The device redirects only SSH connection requests destined for the SSH redirect listening port.
The redirected SSH connection is terminated if the SSH redirect listening port for the connection is
modified.

Table of Contents

Other manuals for H3C MSR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C MSR Series and is the answer not in the manual?

H3C MSR Series Specifications

General IconGeneral
CategoryNetwork Router
IPv6 SupportYes
DimensionsVaries by model
WeightVaries by model
Product TypeModular Router
PortsVaries by model
WAN InterfacesVaries by model
FirewallYes
QoSYes
Wireless SupportVaries by model
USB PortsVaries by model
Console PortYes
Power SupplyVaries by model
RedundancyVaries by model
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity5% to 95% non-condensing
SeriesMSR
CertificationsCE, FCC, RoHS

Related product manuals