EasyManua.ls Logo

NEC Univerge SV9100 - Page 1208

NEC Univerge SV9100
1402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1208
Program
Number
Program Name/Description
Input Data
Default
24-02-10
System Options for Transfer Disconnect
Trunk-to-Trunk
Determine the time a conversation continues
after the timer in Program 24-02-07 expires. If
this option is set to 0, the conversation is
disconnected immediately. This program has
no affect if Program 24-02-07 is set to 0. One of
the trunks used must be an analog trunk (or
leased line).
0 ~ 64800 seconds
0
25-07-07
System Timers for VRS/DISA Long
Conversation Warning Tone Time
Determine the time a DISA caller or any
trunk-to-trunk (such as Tandem Trunking)
conversation can talk before the Long
Conversation tone is heard.
0 ~ 64800 seconds
3600
25-07-08
System Timers for VRS/DISA Long
Conversation Disconnect Time
Determine the time the system waits before
disconnecting a DISA or any trunk-to-trunk
(such as Tandem Trunking) conversation call
after the Long Conversation tone is heard.
0 ~ 64800 seconds
10
80-01-02
Service Tone Setup Basic Tone Number
1 ~ 33
(35)
Edit the warning service tone in the system.
0 = No Tone
33 = Default Time Slot
Operation
Method A Tandem Trunking from Conference
To set up a Tandem Call:
1.
Place or answer first trunk call.
2.
Press Conf softkey.
3.
Place or answer second trunk call.
4.
To set up the tandem call, press Conf twice.
This sets up a Conference between you and both outside parties.
5.
Press Transfer.
- OR -
Press Hold and dial 753 or the service code set for Unsupervised Conference/Tandem Trunking
in
Program 11-12-57.
The line keys for the trunks blink green as long as the Unsupervised Conference continues.
To end the Tandem Call:
1.
Press either flashing line key.
The line keys light steadily (green). You can listen (i.e., monitor) to the call or rejoin the conversation,
based on the setting in Program 20-13-10.

Table of Contents