Guide to Feature Programming
Setting Up Alarms:
Program
Number
Program Name/Description
Input Data
Default
90-10-01
System Alarm Setup Alarm Type
Set the alarm type 14 and 60.
Alarm 14 GCD-CP10-LAN Link Error (IP
Layer 1)
Assign a Major or Minor alarm status to the
LAN link. This program also assigns whether or
not the alarm is displayed to a key telephone
and whether or not the alarm information is
reported to the predefined destination.
Alarm 57 IP Duplication Alarm
Assign a Major or Minor alarm status to the IP
Duplication Alarm.
Alarm 60 SIP Registration Error
Notification
Assign a Major or Minor alarm status to the SIP
Registration Error. This program also assigns
whether or not the alarm is displayed to a key
telephone and whether or not the alarm
information is reported to the predefined
destination.
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0
90-10-02
System Alarm Setup Report
Assign whether or not the alarm is displayed to
a multiline terminal and whether or not the
alarm information is reported to the predefined
destination in Program 90-11.
0 = No Report (no autodial)
1 = Report (autodial)
0
90-24-01
System Alarm Report Notification Time
Setup Month
Set the month for the alarm report to print.
Month 00 ~ 12
00
90-24-02
System Alarm Report Notification Time
Setup Day
Set the day for the alarm report to print.
Day 00 ~ 31
00
90-24-03
System Alarm Report Notification Time
Setup Hour
Set the hour for the alarm report to print.
Hour 00 ~ 23
00