EasyManua.ls Logo

NEC Univerge SV9100 - To Initiate a Voice over to a Busy Extension

NEC Univerge SV9100
1402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1331
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
11-12-41
Service Code Setup (for System Access)
Voice Over
Set the service code used for the Voice Over
feature.
To use Service Code 690 for Voice Over,
Program 11-16-08 (Single Digit Service Code Setup
Voice Over) must be undefined.
MLT
0 ~ 9,
*
, # Maximum of eight
digits
890
11-16-08
Single Digit Service Code Setup Voice
Over
Set the Service code used for the Voice Over
feature.
0 ~ 9,
*
, # Maximum of one digit
6
15-07-01
Programmable Function Keys
Assign a function key for Voice Over (code 48).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-13-06
Class of Service Options (Supplementary
Service) Automatic Off-Hook Signaling
(Automatic Override)
Allow a busy extension to Manually (0) or
Automatically (1) receive off-hook signals.
This setting is to receive incoming call
signaling information during call queuing.
0 = Off
1 = On
COS 1 ~ 15 = 1
21-01-03
System Options for Outgoing Calls Trunk
Interdigit Time (External)
Program the time an extension must wait
before using the Voice Over feature can be
used on a call (this time expires before putting a
call in a talk state). This time also affects
Barge-In.
0 ~ 64800 seconds
5
Operation
To initiate a Voice Over to a busy extension:
1.
Press Voice Over key (Program 15-07 or SC 851: 48)
-
OR -
Dial 8.
-
OR -
Dial 890.
You hear an alert tone and the Voice Over key flashes. You can talk to the called party after the alert
tone ends.