EasyManua.ls Logo

NEC Univerge SV9100 - Alarm Report Definitions

NEC Univerge SV9100
1402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
Alarm Report Definitions
Alarm Report Heading Definitions
LVL
Alarm Type (MAJ = Major, MIN = Minor)
NO
Number of Alarm (4-digit)
STAT
Status (REC = Recovered, ERR = Error, WAR = Warning
DATE
Date the Alarm Occurred
TIME
Time the Alarm Occurred
ITEM
Name of the Alarm
UNIT
Name of the Blade
SLT
Chassis Slot Number
PRT
Chassis Port Number
PARAMETER
Related Information
PKG Installation
Blade is removed or inserted.
ISDN Link
ISDN Line failure is detected.
GCD-CP10 LAN Link
GCD-CP10 LAN connection failure is detected.
Blocking
Terminal Failure may have occurred because terminal blocking is detected. Terminal
is unplugged or wire is disconnected.
System Data Change
System Upgrade performed or Programming change.
System Start Up
System is reset.
SMDR Link
Connection failure is detected between the GCD-CP10 and SMDR printer device.
STA
DSP for IP Station Call were all busy.
TRK
DSP for Trunk Call were all busy, includes SIP trunks.
LNK
DSP for Net-Link Call were all busy.
NET
DSP for CCISoIP Networking Call were all busy.
System Information
The system can print a report of the blades installed, the port assignments, and the port types. This
information is sent to the extension defined in Program 90-13.
The System Information Reports indicate:
Date and Time of the Report
Blade names
Slot condition (working, blocked)
Port assignment
Port classification

Table of Contents