433
The power to TEL 101 and TEL 102 cuts at night.
Automatic Night Service
Settings Using Service Codes
< Program >
Program 15-27-01:
TEL 101: Power Save Group 2
TEL 102: Power Save Group 2
Power Off for Power Save Group 2
1.
Press Speaker and dial (Service Code 731).
2.
Dial 02, Group 2
3.
Dial 1, Power Off
4.
Enter the Password (Default: 0000)
Power supply to the system is cut when all terminals of Power Save group 2 are in an Idle state.
Password is set in Program 90-02-02 (User ID3).
5.
Press Speaker to set Power Off for Power Save Group 2.
Power On for Power Save Group 2
1.
Press Speaker and dial (Service Code 731).
2.
Dial 02, Group 2
3.
Dial 0, Power On
4.
Press Speaker to set Power On for Power Save Group 2.