428
Ecology
Description
Environmental issues, such as global warming or ecology are one of the most
important themes
in today's world. The following energy saving features are
implemented in this system:
Power Cut Off Mode:
Based on Day/Night mode switching, the system can automatically cut power to
pre-programmed multiline terminals resulting in the system consuming less
power. This
feature can also be activated/deactivated via service codes.
When the system cuts the
power to the terminal it cannot be used again until
power is restored.
Power Saving Mode:
Based on a configurable system timer, preprogrammed multiline terminals can
dim the
brightness of all line keys and feature keys using less power. This
feature does not affect
the multiline terminal display.
Power Failure Saving Mode:
If the SV9100 loses system power, this feature can be programmed to cut the
power to
selected terminals while running on the backup battery. Cutting the
power to specific
terminals will help extend battery backup run time. This
feature is programmed on a per
station basis and is NOT enabled by default.
When a terminal is in the Power Cut off/Power Failure mode, a user cannot dial any
number including an emergency
number (i.e., 911) from the station. The terminal is unusable until it returns from the power cutoff state.
Conditions
Power Cut Off Mode
While in power cut off mode, power does not automatically recover. If
this is
expected to occur, disable the Ecology mode before license
expiration, or reboot the
system to restore power to the telephones.
The system can cut power to digital (TDM) Multiline Terminals by using
power save
groups. A maximum of 16 Power Save groups are
supported.
The Power Cut Off mode can be set to On or Off on a per group
basis. However,
Digital Station port 1 cannot be set for power cutoff.
This keeps the terminal
powered on for emergency calls, etc.
If some terminals are on a call when the Power Cut Off mode is enabled,
the system
will wait until all extensions on the blade become idle
before cutting power to the
slot.
Power Cut Off mode can be set to On or Off using one or a combination of the following
methods:
Night mode time schedule/Manual Night Mode selection
Service Code
Function Key