846
Guide to Feature Programming
For additional programming for Paging, refer to the features Paging, External and Paging, Internal.
Program
Number
Program Name/Description
Input Data
Default
15-07-01
Programmable Function Keys
Assign function keys for Conference (code 07).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-10-06
Class of Service Options (Answer Service)
Meet-Me Conference and Paging
Turn Off or On an extension user ability to use
Meet-Me Conference and Paging.
0 = Off
1 = On
COS 1 ~ 15 = 1
31-01-04
System Options for Internal/External Paging
Privacy Release Time
Set the Privacy Release Time. After the user
initiates Meet Me Conference, the system waits
this interval for the Paged party to join the
conversation.
0 ~ 64800 seconds
90
Operation
Meet Me External Conference
To make a Meet Me External Conference:
Multiline Terminal
1.
While on a call, press Conf softkey.
2.
Dial *1 and the Combined Paging Zone code 1~8 (for Internal/External Zones 1~8) or 0 (for
Internal/External All Call).
3.
Announce the zone.
4.
When a co-worker answers your page, press Conf softkey twice.
5.
Repeat steps 1~4 for each co-worker you want to add.
Single Line Telephone
1.
While on a call, hookflash and dial #1.
2.
Dial 803 and the External Paging zone code (1~8 or 0 for All Call).
- OR -
Dial *1 and the Combined Paging Zone code 1~8 (for Internal/External Zones 1~8) or 0 (for

Table of Contents