898
Tie Lines:
Program
Number
Program Name/Description
Input Data
Default
10-09-01
DTMF and Dial Tone Circuit Setup
If the system has DTMF Tie Lines, be sure to
reserve at least one circuit for analog trunk
DTMF reception (type 0 or 2).
Use the following as a guide when allocating
DTMF receivers:
In light traffic sites, allocate one DTMF
receiver for every 10 devices that use them.
In heavy traffic sites, allocate one DTMF
receiver for every five devices that use them.
0 = Common Use
1 = Extension Only
2 = Trunk Only
Circuit/Resource
01 ~ 08 = 1
(Extensions)
Circuit/Resource
09 ~ 32 = 2
(Trunks)
Circuit/Resource
33 ~ 144 = 0
(Common)
When
GPZ-BS10 is
installed, 81 ~
144 are available
14-01-02
Basic Trunk Data Setup Transmit Level
Customize the transmit level of the CODEC
Gain for each trunk.
Trunks 1 ~ 400
1 ~ 57 (-15.5 ~ +12.5dB in 0.5dB
intervals)
32 (0dB)
14-01-03
Basic Trunk Data Setup Receive Level
Customize the receive level of the CODEC
Gain for each trunk as required.
Trunks 1 ~ 400
1 ~ 57 (-15.5 ~ +12.5dB in 0.5dB
intervals)
32 (0dB)
14-01-13
Basic Trunk Data Setup Trunk-to-Trunk
Transfer
Enable loop supervision for each Tie Line that
should be able to place outgoing calls.
0 = Disable
1 = Enable
1
14-02-01
Analog Trunk Data Setup Signaling Type
(DP/DTMF)
Set the outgoing signaling type for the tie trunk.
To set incoming signaling, refer to Program
34-01-02.
0 = Dial Pulse (10 PPS)
1 = Dial Pulse (20 PPS)
2 = DTMF
2
14-05-01
Trunk Group Trunk Group Number
Program Tie Lines of similar type into the same
trunk group. The system uses trunk groups for
outgoing access to Tie Lines (i.e., Service Code
704 + group). Also see Program 34-05-01.
Trunk Port 1 ~ 400 =
Priority 1 ~ 400
Default = Trunks
1 ~ 400 assigned
to trunk group 1
with priorities
equal to the
trunk number.
Trunk 1 = Priority
1 Trunk 400 =
Priority 400.
14-06-01
Trunk Group Routing Priority Order
Number
Set the priority order number 1 ~ 4.
0 = Not Specify
1 ~ 100: (Trunk Group Number)
101 ~ 150: (100 + Networking
System Number)
1001 ~ 1100: (1000 + Route
Table Number)
Route 1, Order
Number 1 = 1
(Trunk Group 1)
Order Numbers
2, 3, 4 = 0 (Not
Specified)
All Other Routes
(2 ~ 100) and
Order Numbers
(1 ~ 4) = 0 (Not
Specified).

Table of Contents