Facsimile CO Branch Connection
Description
The UNIVERGE SV9100 system provides branch connection of locally provided
facsimile
machines to CO/PBX lines. Additional dedicated CO/PBX lines are not
required for a facsimile to
operate. The facsimile shares any CO/PBX line on the
COI Package and Power Failure (PF)
circuit.
Conditions
This function requires a GCD-4COTA Blade to connect a facsimile in
branch to a
direct CO/PBX line.
A PF circuit is required. The GCD-4COTA has PF circuits on the first two ports.
PF and FAX branch connection do not work together at the same port.
Select either
way in Program 14-02-21.
For the FAX Branch Line, Incoming Group or DIL should be programmed.
The systems cannot distinguish between an incoming facsimile call and
a CO/PBX
call. Incoming call may be automatically answered by FAX
Machine. Ringing
assignments should be turned off for fax lines.
When the facsimile is used, the associated CO line key indicates
Busy LED on a
multiline terminal.
When the facsimile is not used, the FAX Branch CO/PBX line can be
used as an
outside line.
Code restriction does no apply to outgoing calls from the FAX machine.
Connection of the facsimile machine does not require extra system ports.
The GPZ-4COTE daughter board does not contain any Power Fail or
FAX Branch
Exchange circuits.
Power Fail and FAX CO Branch Connection cannot be used on the
same CO port at
the same time.
Program 14-02-21 must be used to set a CO port to use this feature.
Default Settings
None
System Availability
Terminals
None
Required Component(s)