Program
Number
Program Name/Description
Input Data
Default
20-54-01
Power Supply Mode for Each Power Save
Group Power Saving Mode
Assign the Power Saving mode in each Power
Saving group and Night mode.
Power Save Group Number
1 ~ 16
Night Mode 1 ~ 8
0 = Power Cut
1 = Power Supply
1
90-02-02
Programming Password Setup Password
Configure the administrator accounts that are
used when Power cut to the Power Save group.
Maximum of eight digits.
Operation
Power Cut Off Mode
To cut the power for Power Save Group 2 during the night time (19:00-6:00):
< Program >
Program 20-53-01: Power Save Group 2 Set 1 for Night mode Service Group Number
Program 20-53-01: Power Save Group 3 Set 1 for Night mode Service Group Number
Program 20-54-01: Power Save Group 2
Night Mode 1: Power Saving Mode 1 (Power Supply)
Night Mode 2: Power Saving Mode 0 (Power cut)
Program 20-54-01: Power Save Group 3
Night Mode 1: Power Save Mode 1 (Power Supply)
Night Mode 2: Power Save Mode 1 (Power cut)
Program 15-27-01:
TEL 101: Power Save Group 2
TEL 102: Power Save Group 2
TEL 103: Power Save Group 3
TEL 104: Power Save Group 3
Program 12-02: Automatic Night Service Patterns
Night Group
Time Pattern
Mode
Set Time
Number
Start
End
Night Mode
1
1
1
0000
0600
2
1
1
2
0600
1900
1
1
1
3
1900
0000
2