EasyManua.ls Logo

NEC Univerge SV9100 - Page 129

NEC Univerge SV9100
1402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
129
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
15-07-01
Programmable Function Keys
Assign functions to multiline terminal line keys.
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
20-02-23
System Options for Multiline Telephones
UX5000 Phone Operation Mode
Selects the Loop Key operation like the
UX5000 terminal, or the CAP Key operation like
the SV9100 terminal.
0 = Original Operation Mode
(CAP Key)
1 = UX5000 Special Operation
Mode (Loop Key)
0
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to
extensions.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-11-19
Class of Service Options (Hold/Transfer
Service) Hold/Extended Park
Determine whether an extension Class of
Service should allow normal or extended Park
(0 = Normal for Program 24-01-06, 1 =
Extended for Program 24-01-07).
0 = Off
1 = On
COS 1 ~ 15 = 0
24-01-01
System Options for Hold Hold Recall Time
A call on Hold recalls the extension that placed
it on Hold after this time. This time works with
the Hold Recall Callback Time.
0 ~ 64800 seconds
90
24-01-02
System Options for Hold Hold Recall
Callback Time
A call that is parked longer than the
programmed time recalls the extension where it
was initially parked.
0 ~ 64800 seconds
30