201
Program
Number
Program Name/Description
Input Data
Default
21-01-16
System Options for Outgoing Calls
Supervise Dial Detection Timer
With the Outgoing Disable on Incoming Line
feature, if dial tone is not detected after the
extension answers an incoming line, the system
determines the call is unable to complete and
releases the DTMF receiver.
0 ~ 64800 seconds
20
21-01-17
System Options for Outgoing Calls
Restriction Digit in Outgoing Disable on
Incoming Line
With the Outgoing Disable on Incoming Line
feature, determine the number of digits to be
dialed before the call should be disconnected.
Digits 1 ~ 9
4
21-02-01
Trunk Group Routing for Extensions
Assign Program 14-06 routes to extensions.
0 ~ 100
0 = No Setting (Calls will not
route.)
1
21-15-01
Individual Trunk Group Routing for
Extensions
Designate the trunk route accessed when a
user dials the Alternate Trunk Route Access
Code. Refer to Trunk Group Routing to set up
outbound routing.
0 ~ 100
0 = No Setting (Calls will not
route.)
0
24-02-07
System Options for Transfer Trunk-to-
Trunk Transfer Release Warning Tone
Timer starts when a trunk begins talking with
another trunk (for example: Trunk-to-Trunk
Transfer, outgoing from trunk, Tandem
Trunking). When this time expires, a warning
tone is heard.
0 ~ 64800 seconds
1800
24-02-10
System Options for Transfer Disconnect
Trunk to Trunk Timer
Timer starts after the Warning Tone is heard
(24-02-07). When time expires, the trunk is
disconnected.
0 ~ 64800 seconds
0
82-08-01
Sidetone Volume Setup
Adjust of the multiline terminal side tone
volume. There are two levels, based on
whether the connected trunk is a digital trunk or
analog trunk.
Input Data (Digital Sidetone
Level: Analog Sidetone Level)
0 (-54 dB : -54 dB)
1 (-48 dB : -54 dB)
2 (-42 dB : -54 dB)
3 (-36 dB : -48(dB)
4 (-30 dB : -42 dB)
5 (-24 dB : -36 dB)
6 (-18 dB : -30 dB)
7 (-12 dB : -24 dB)
8 (-12 dB : -18 dB)
9 (-12 dB : -12 dB)
6