323
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
20-09-05
Class of Service Options (Incoming Call
Service) Signal/Voice Call
Turn Off or On an extension user ability to
enable Handsfree Answerback or Forced
Intercom Ringing for their incoming Intercom
calls.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-09-06
Class of Service Options (Incoming Call
Service) Incoming Time Display
If this option is set to 1, the Incoming Call Time
is displayed on the multiline terminal LCD while
the telephone is ringing.
Caller ID should be enabled for this feature in
Program 20-09-06 to function.
0 = Off
1 = On
COS 1 ~ 15 = 0
20-09-07
Class of Service Options (Incoming Call
Service) Call Queuing
Turn Off or On an extension user ability to have
calls queued if a call rings the extension when it
is busy.
Program 20-13-06 must be set to 0 (Off) for
this feature to work.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-13-05
Class of Service Options (Supplementary
Service) Intercom Off-Hook Signaling
Turn Off or On an extension ability to send
off-hook signals.
This setting functions with Programs 20-09-07
and 20-13-06 disabled.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-13-06
Class of Service Options (Supplementary
Service) Automatic Off-Hook Signaling
(Automatic Override)
Allow a busy extension user to Manually (0) or
Automatically (1) receive off-hook signals.
This setting is to receive incoming call
signaling information during call queuing.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-13-35
Class of Service Options (Supplementary
Service) Block Camp-On
Turn Off or On an extension user ability to block
callers from dialing to camp-on.
0 = Off
1 = On
COS 1 ~ 15 = 0