334
Program
Number
Program Name/Description
Input Data
Default
11-11-27
Service Code Setup (for Setup/Entry
Operation) Destination of Automatic
Transfer Each Extension Group
Set the service code for setting the destination
for immediate automatic transfer for ICM and
transferred calls to Department Groups.
MLT
0 ~ 9,
*
, # Maximum of eight
digits
704
11-11-28
Service Code Setup (for Setup/Entry
Operation) Delayed Transfer for Every
Extension Group
Set the delayed transfer destination
Department Group.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
705
11-11-29
Service Code Setup (for Setup/Entry
Operation) Delayed Transfer Cancellation
for Each Extension Group
Cancel the delayed transfer destination
Department Group.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
706
11-12-09
Service Code Setup (for Service Access)
Change to STG (Department Group) All Ring
Set the service code for ringing all members of
a Department Group.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
No Setting
11-16-10
Single Digit Service Code Setup
(Department) STG All Ring Mode
Assign the Single Digit (post-dialing) Service
Code for All Member Ring.
0 ~ 9,
*
, # Maximum of one digit
No Setting
15-07-01
Programmable Function Keys
Assign a Department Calling key (46) so
extension users can install or remove
themselves from the Department Calling
Group. Additional keys can also be assigned for
Department Group features immediate calling
destination (58), delayed calling destination
(59) and DND destination (60).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
16-01-01
Department Group Basic Data Setup
Department Name
Assign a name to the Extension (Department)
Groups.
Maximum of 12 characters
No Setting
16-01-02
Department Group Basic Data Setup
Department Calling Cycle
Set the routing cycle for calls into a department
(i.e., when a user dials the department pilot
number). The system can ring the highest
priority extension available (Priority Routing, 0)
or cycle in circular order to a new idle extension
for each new call (Circular Routing, 1).
0 = Normal Routing (Priority)
1 = Easy UCD Routing
(Circular)
0