36
Program
Number
Program Name/Description
Input Data
Default
10-12-02
GCD-CP10 Network Setup Subnet Mask
The setting of Subnet Mask is invalid when all
Host Addresses are 0.
If the network section is:
0,
127,
128.0,
191.255,
192.0.0,
223.255.255
The setting of Subnet Mask is invalid.
128.0.0.0 | 192.0.0.0 | 224.0.0.0
|240.0.0.0 | 248.0.0.0 | 252.0.0.0
|254.0.0.0 | 255.0.0.0
|255.128.0.0 | 255.192.0.0 |
255.224.0.0 | 255.240.0.0
|255.248.0.0 | 255.252.0.0
|255.254.0.0 | 255.255.0.0 |
255.255.128.0 | 255.255.192.0
|255.255.224.0 | 255.255.240.0
|255.255.248.0 | 255.255.252.0
|255.255.254.0 | 255.255.255.0 |
255.255.255.128
|255.255.255.192
|255.255.255.224
|255.255.255.240
|255.255.255.248
|255.255.255.252
|255.255.255.254
|255.255.255.255|
255.255.255.0
10-12-03
GCD-CP10 Network Setup Default
Gateway
Assign the default gateway IP address for the
GCD-CP10.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
90-10-02
System Alarm Setup Report
When enabled the system will provide
notification of events for each of the enabled
reports. This does not have to be set for
DIMLast/DIMDump files to be sent.
0 = No Report (no autodial)
1 = Report (autodial)
0
90-11-02
System Alarm Report Report Method
When Alarm Reports are to be emailed, set this
option to 1. Email address set in Program
90-11-08
0 = No Report
1 = Email Address
0
90-11-06
System Alarm Report SMTP Host Name
When Alarm Reports are to be emailed, set the
SMTP name (for example, smtp.yourisp.com).
Contact your ISP (Internet Service Provider) for
the correct entry if needed.
Maximum of 255 characters
No Setting
90-11-07
System Alarm Report SMTP Host Port
Number
When Alarm Reports are to be emailed, set the
SMTP host port number. Contact your ISP
(Internet Service Provider) for the correct entry
if needed.
0 ~ 65535
25
90-11-08
System Alarm Report To E-mail Address
When Alarm Reports are to be emailed, set this
email address to where the report should be
sent.
Maximum of 255 characters
No Setting
90-11-09
System Alarm Report Reply Address
When Alarm Reports are to be emailed, set the
email address where replies should be emailed.
Maximum of 255 characters
No Setting