Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
11-12-42
Service Code Setup (for Service Access)
Flash on Trunk lines
Customize the flash on trunk lines Service
Codes.
SLT
0 ~ 9,
*
, # Maximum of eight
digits
#3
11-12-59
Service Code Setup (for Service Access)
Trunk Drop Operation for SLT
Customize the trunk drop operation for single
line telephone Service Codes.
SLT
0 ~ 9,
*
, # Maximum of eight
digits
No Setting
14-02-03
Analog Trunk Data Setup Flash Type
Select the flash type.
0 = Open Loop Flash
1 = Ground
Always set this option for Open
Loop Flash (0)
0
14-02-04
Analog Trunk Data Setup Hooking Type
Use Flash for Timed Flash (Program 81-01-14)
or Disconnect (Program 81-01-15). (A user can
press the FLASH key while on a trunk call to
implement Flash.)
0 = Timed Flash (Hooking)
1 = Disconnect (Cut)
0
15-02-05
Multiline Telephone Basic Data Setup
Transfer Key Operation Mode
If the Conf key should access Flash, enter 2.
Otherwise, enter 0 or 1.
0 = Transfer
1 = Serial Call
2 = Flash
0
15-03-04
Single Line Telephone Basic Data Setup
Flashing
Enable/Disable Flash for single line (500/2500
type) telephones.
0 = No
1 = Yes
1
15-07-01
Programmable Function Keys
Assign a function key for Drop Key (code 84) if
required.
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)

Table of Contents

Other manuals for NEC Univerge SV9100

Related product manuals