58
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
14-02-09
Analog Trunk Data Setup Busy Tone
Detection
Enable/Disable Busy Tone Detection.
0 = Disable (No)
1 = Enable (Yes)
0
14-02-14
Analog Trunk Data Setup Loop Start/
Ground Start
Identify the analog trunk as either loop or
ground start.
0 = Loop Start (Loop)
1 = Ground Start (Ground)
0
80-04-01
Call Progress Tone Detector Setup
Detection Level
Set the Detection Level.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
Type 1 (DT) 0
(-25dBm)
Type 2 (BT) 0
(-25dBm)
Type 3 (RBT) 0
(-25dBm)
Type 4, Type 5
0
80-04-02
Call Progress Tone Detector Setup Min.
Detection Level
Set the minimum detection level.
0 ~ 15
detect level 0:
-15dBm (0) to -30dBm(15)
detect level 1:
-30dBm (0) to -45dBm(15)
detect level 2:
-40dBm (0) to -55dBm(15)
Type 1 (DT) 15
(-25dBm)
Type 2 (BT) 15
(-25dBm)
Type 3 (RBT)
15
(-25dBm)
Type 4, Type 5
0
80-04-03
Call Progress Tone Detector Setup S/N
Ratio
Set the Signal to Noise ratio.
0 ~ 4
(0dB ~ -20dB)
Type 1 (DT) = 4
(-20dB)
Type 2 (BT) = 4
(-20dB)
Type 3 (RBT) = 4
(-20dB)
Type 4 = 0
Type 5 = 0