Program
Number
Program Name/Description
Input Data
Default
47-01-13
SV9100 InMail System Options Number of
RNA Rings
If a non-pager callout rings the destination
longer than this number of times, InMail marks
the call as unanswered (Ring No Answer) and
hangs up.
1 ~ 99 (rings)
5
47-01-14
SV9100 InMail System Options Number of
Cascading Attempts
Set how many times InMail retries an
incomplete Message Notification callout. This
total includes unacknowledged callouts,
callouts to a busy destination, and callouts to an
unanswered destination. This option applies to
pager and non-pager callouts.
1 ~ 99 (rings)
1
47-01-15
SV9100 InMail System Options Send Pager
Callout Until Acknowledged
When this option is set to 1, InMail continues to
retry a digital pager Message Notification
callout until the notification is acknowledged. If
this option is set to 0, InMail retries a digital
pager Message Notification the number of
times specified in 47-01-14 Number of Callout
Attempts. This option does not apply to
Message Notification callouts to telephone
numbers.
A digital pager notification is acknowledged
when the recipient logs onto the mailbox.
0 = No (Disabled)
1 = Yes (Enabled)
0
47-01-16
SV9100 InMail System Options Name
Format
Specify how names are displayed.
0 = 1st Last
1 = Last 1st
0
47-02-01
SV9100 InMail Station Mailbox Options
Mailbox Type
Enable/Disable the mailbox. An extension
mailbox is not accessible when it is disabled
(even though its stored messages and
configuration are retained in memory.) If
disabled, a user pressing Message initiates a
remote Logon and is asked to enter their
mailbox number. A voice prompt then
announces: That mailbox does not exist.
To make programming easier, consider
associating a mailbox number with a station
port. For example, mailbox 1 could correspond
to port 1, which in turn corresponds to
extension 101.
0 = None
1 = Personal
2 = Group
1