595
Program
Number
Program Name/Description
Input Data
Default
47-02-07
SV9100 InMail Station Mailbox Options
Recording Conversation Beep
Enable/Disable the Conversation Record beep.
If enabled, all parties on a call hear the voice
prompt Recording followed by a single beep
when the extension user initiates Conversation
Record. If disabled, the voice prompt and beep
do not occur. When you disable the
Conversation Record beep, the following voice
prompts do not occur while InMail records the
conversation:
Recording (followed by a beep)
That mailbox is full (if the mailbox message
storage capacity is reached)
You have reached the recording limit (if the
recorded message is too long)
The SV9100 telephone system software
provides an additional Conversation Record
beep. This beep repeats according to the
setting of Program 45-01-06: Voice Mail
Integration Options: Record Alert Tone
Interval Time.
0 = Disable
1 = Enable
1
47-02-08
SV9100 InMail Station Mailbox Options
Message Waiting Lamp
Enable/Disable Message Waiting lamp at the
extension associated with the Subscriber
mailbox. For Subscriber Mailboxes, you should
enable this option. For Guest Mailboxes, you
should disable it.
0 = Disable
1 = Enable
1
47-02-09
SV9100 InMail Station Mailbox Options
Auto Attendant Direct to Voice Mail
Enable/Disable Auto Attendant Do Not Disturb.
When a subscriber enables this option, an
Automated Attendant caller routes directly to
the mailbox, hears the greeting, and is asked to
leave a message. A subscriber can also enable
this option while recording their mailbox
greeting.
0 = Disable
1 = Enable
0
47-02-10
SV9100 InMail Station Mailbox Options
Forced Unscreened Transfer
Enable/Disable Automated Attendant Forced
Unscreened Transfer for the Subscriber
Mailbox. If enabled, each Screened Transfer
(TRF) to the extension is converted to an
Unscreened Transfer (UTRF). If disabled,
Screened Transfers from the Automated
Attendant occur normally.
0 = Disable
1 = Enable
0