Program
Number
Program Name/Description
Input Data
Default
84-14-15
SIP Trunk Basic Information Setup 100rel
Settings
This program specifies if the 100rel message is
included or not.
When set to a 0 (Use Default Settings), the
100rel will be included in the initial SIP Invite
and any provisional 1XX responses (excluding
the 100 trying).
When set to a 1 (Use opposite settings), the
100rel will NOT be included in the initial SIP
Invite and provisional 1XX responses
(excluding the 100 trying)
0 = Use Default Settings (100rel
included)
1 = Use Opposite Settings
(100rel not included)
(Profile 1 ~ Profile 2)
0
84-26-01
IPL Basic Setup IP Address
Assign the IP address for each DSP on the
GPZ-IPLE.
xxx.xxx.xxx.xxx
172.16.0.20
84-26-02
IPL Basic Setup RTP Port Number
Assign the RTP port number to be used for
each DSP on the GPZ-IPLE.
Only even numbered ports are supported.
0 ~ 65534
10020
84-26-03
IPL Basic Setup RTCP Port Number (RTP
Port Number + 1)
Define the TCP port number for RTCP to use
for each DSP.
0 ~ 65534
10021
84-34-01
VoIPDB DTMF Setup DTFMF Relay Mode
This program enables or disables DTMF Relay
for Type 3 SIP Trunk.
0 = Disable
1 = RFC2833
2 = H.245
0
(For type 1 ~ 6)
90-10-01
System Alarm Setup Alarm Type
Define if Alarms are Minor, Major, or Not Set.
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
No Setting
SIP Trunk E.164 Support
Program
Number
Program Name/Description
Input Data
Default
10-02-01
Location Setup Country Code
Enter the country code.
Dial (maximum of four digits)
0 ~ 9,
*
, #
1
10-02-02
Location Setup International Access
Codes
Enter the international access code.
Dial (maximum of four digits)
0 ~ 9,
*
, #
No Setting