906
Program
Number
Program Name/Description
Input Data
Default
80-03-08
DTMF Tone Receiver Setup OFF Detect
Time
Define the Off detection time for DTMF Tone
Receiver.
1 ~ 255
(15+ 15ms ~ 3825ms)
Type 1 ~ 5 = 1
(30ms)
80-04-01
Call Progress Tone Detector Setup
Detection Level
Define the detection levels for the Call Progress
Tone Detector.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
Type 1 (DT) 0
(-25dBm)
Type 2 (BT) 0
(-25dBm)
Type 3 (RBT) 0
(-25dBm)
Type 4, Type 5
0
80-04-02
Call Progress Tone Detector Setup Min.
Detection Level
Define the minimum detection levels for the Call
Progress Tone Detector.
0 ~ 15
detect level 0:
-15dBm (0) to -30dBm(15)
detect level 1:
-30dBm (0) to -45dBm(15)
detect level 2:
-40dBm (0) to -55dBm(15)
Type 1 (DT) 15
(-25dBm)
Type 2 (BT) 15
(-25dBm)
Type 3 (RBT)
15
(-25dBm)
Type 4, Type 5
0
80-04-03
Call Progress Tone Detector Setup S/N
Ratio
Define the S/N ratio for the Call Progress Tone
Detector.
0 ~ 4 (0dB ~ -20dB)
Type 1 (DT) 4
(-20dB)
Type 2 (BT) 4
(-20dB)
Type 3 (RBT) 4
(-20dB)
Type 4, Type 5
0
80-04-04
Call Progress Tone Detector Setup No
0 ~ 255 (30 + 30 ~ 7680ms)
Type 1 (DT)
Tone Time
(0 = not detect)
132 (3990ms)
Define the no tone time for the Call Progress
1 ~ 255 = 60 ~ 7680ms
Type 2 (BT)
Tone Detector.
The formula is 30 + 30N. When
set to N = 1, it means 30
132 (3990ms)
Type 3 (RBT)
+ 30 * 1 = 60.
132 (3990ms)
When set to N=255, it means
Type 4, Type 5
30+30*255=7680
0
80-04-05
Call Progress Tone Detector Setup Pulse
Count
Define the pulse count for the Call Progress
Tone Detector.
1 ~ 255
Type 1 (DT) 1
Type 2 (BT) 1
Type 3 (RBT) 1
Type 4, Type 5
0