SP5-816-208 Error Codes
Cause Code Meaning Solution/ Workaround
Operation Error,
Incorrect Setting
-12002
Inquiry, registration attempted
without acquiring Request No.
Obtain a Request Number
before attempting the Inquiry or
Registration.
-12003 Attempted registration without
execution of a confirmation and no
previous registration.
Perform Confirmation before
attempting the Registration.
-12004 Attempted setting with illegal entries
for certification and ID2.
Check ID2 of the mainframe.
-12005 @Remote communication is
prohibited. The device has an
Embedded RC gate-related
problem.
Make sure that "Remote
Service" in User Tools is set to
"Do not prohibit".
-12006 A confirmation request was made
after the confirmation had been
already completed.
Execute registration.
-12007 The request number used at
registration was different from the
one used at confirmation.
Check Request No.
-12008
Update certification failed because
mainframe was in use.
Check the mainframe
condition. If the mainframe is in
use, try again later.
-12009 The ID2 in the NVRAM does not
match the ID2 in the individual
certification.
Check ID2 of the mainframe.
-12010 The certification area is not
initialized.
Initialize the certification area.
2. Installation