SC161-20 D IPU Error (DRAM Initialization Trouble)
An IPU error (DRAM initialization trouble) is issued if DDR-PHY initialization
and the Training status check result in an error with power on or recovering
from Power Save mode.
IPU board defective (Connection problem of Macaron/DRAM device)
DRAM device defective
SC reproducibility check
Reproducible
Do the items below.
Connection
Check that all connectors are connected correctly (no loose
connector/not fully connected).
No SC is generated.
End
An SC is generated.
IPU/BICU trouble
IPU/BICU trouble
Replace IPU/BICU
No SC is generated.
End
An SC is generated.
Replace the machine/design analysis