EasyManua.ls Logo

Ricoh MP CW2201 - Page 996

Ricoh MP CW2201
1176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5404 User Code Count Clear
[EXECUTE]
5411 LDAP Certification
4 Simplified Authentication
[0 or 1/1/1] 1: On, 0: Off
5 Password Null Not Permit
[0 or 1/0/-]
0: Password NULL not permitted.
1: Password NULL permitted.
6 Detail Option
[0 to 0xff/0/0x01] 0: Off 1:On
5412 Krb Certification
(7) 00000000 (0)
5413 Lockout Setting
1 Lockout On/Off
[0 or 1/0/-]
0: Off, 1: On
2 Lockout Threshold
[1 to 10/5/1/step]
3 Cancellation On/Off
[0 or 1/0/-]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user ID and password are entered.
4 Cancellation Time
[1 to 999/60/1 min./step]