EasyManua.ls Logo

SMC Networks LECSN-T Series - Page 192

SMC Networks LECSN-T Series
1046 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. PARAMETERS
5 - 86
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT
EIP
PNT
PT45
HMM
Home
position
return type
Setting
value
Home position return
direction
How to execute
home position return
Setting
value
Home position return
direction
How to execute
home position return
-1
Address increasing
direction
Dog type (Rear end
detection Zphase
reference)/torque
limit changing dog
type (Front end
detection, Zphase
reference)
-33
Address decreasing
direction
Dog type (Rear end
detection Zphase
reference)/torque
limit changing dog
type (Front end
detection, Zphase
reference)
-2
Count type (front
end detection, Z-
phase reference)
-34
Count type (front
end detection, Z-
phase reference)
-3
Data set type/torque
limit changing data
set type
-36
Stopper type
(stopper position
reference)
-4
Stopper type
(stopper position
reference)
-38
Dog type (rear end
detection, rear end
reference)
-6
Dog type (rear end
detection, rear end
reference)
-39
Count type (front
end detection, front
end reference)
-7
Count type (front
end detection, front
end reference)
-40
Dog cradle type
-41
Dog type last Z-
phase reference
-8
Dog cradle type
-42
Dog type front end
reference
-9
Dog type last Z-
phase reference
-43
Dogless Z-phase
reference
-10
Dog type front end
reference
-11
Dogless Z-phase
reference
Setting
value
Home position return
direction
How to execute
home position return
Setting
value
Home position return
direction
How to execute
home position return
3
Address increasing
direction
Method 3
21
Address decreasing
direction
Method 21
4
Address increasing
direction
Method 4
22
Address decreasing
direction
Method 22
5
Address decreasing
direction
Method 5
23
Address increasing
direction
Method 23
6
Address decreasing
direction
Method 6
24
Address increasing
direction
Method 24
7
Address increasing
direction
Method 7
27
Address decreasing
direction
Method 27
8
Address increasing
direction
Method 8
28
Address decreasing
direction
Method 28
11
Address decreasing
direction
Method 11
33
Address decreasing
direction
Method 33
12
Address decreasing
direction
Method 12
34
Address increasing
direction
Method 34
19
Address increasing
direction
Method 19
35
Method 35
20
Address increasing
direction
Method 20
37
Method 37 (Data set
type)
PT46
ESTC
Synchronous
encoder filter
time constant
Set a primary delay filter time constant to the synchronous encoder command.
Setting this parameter reduces vibration. However, a delay in response to the
synchronous encoder will be generated.
A setting value when Synchronous control command (C_STS) is turned on will be
applied to this parameter.
Setting range: 0 to 5000
0
[ms]

Table of Contents