EasyManuals Logo

SMC Networks LECSN-T Series User Manual

SMC Networks LECSN-T Series
1046 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #270 background imageLoading...
Page #270 background image
8. TROUBLESHOOTING
8 - 5
No.
Name
Detail No.
Detail name
Stop
method
(Note 2, 3)
Alarm deactivation
Alarm reset
Communicat
ion
reset
Cycling the
power
Alarm
Initial magnetic pole
detection error
27.1
Initial magnetic pole detection -
Abnormal termination
DB
27.2
Initial magnetic pole detection - Time
out error
DB
27.3
Initial magnetic pole detection - Limit
switch error
DB
27
27.4
Initial magnetic pole detection -
Estimated error
DB
27.5
Initial magnetic pole detection - Position
deviation error
DB
27.6
Initial magnetic pole detection - Speed
deviation error
DB
27.7
Initial magnetic pole detection - Current
error
DB
28
Linear encoder error 2
28.1
Linear encoder - Environment error
EDB
Linear encoder error 1
2A.1
Linear encoder error 1-1
EDB
2A.2
Linear encoder error 1-2
EDB
2A.3
Linear encoder error 1-3
EDB
2A
2A.4
Linear encoder error 1-4
EDB
2A.5
Linear encoder error 1-5
EDB
2A.6
Linear encoder error 1-6
EDB
2A.7
Linear encoder error 1-7
EDB
2A.8
Linear encoder error 1-8
EDB
2B
Encoder counter error
2B.1
Encoder counter error 1
EDB
2B.2
Encoder counter error 2
EDB
30.1
Regeneration heat error
DB
(Note 1)
(Note 1)
(Note 1)
30
Regenerative error
30.2
Regeneration signal error
DB
(Note 1)
(Note 1)
(Note 1)
30.3
Regeneration feedback signal error
DB
(Note 1)
(Note 1)
(Note 1)
31
Overspeed
31.1
Abnormal motor speed
SD
32.1
Overcurrent detected at hardware
detection circuit (during operation)
DB
32
Overcurrent
32.2
Overcurrent detected at software
detection function (during operation)
DB
32.3
Overcurrent detected at hardware
detection circuit (during a stop)
DB
32.4
Overcurrent detected at software
detection function (during a stop)
DB
33
Overvoltage
33.1
Main circuit voltage error
EDB
34
SSCNET receive error 1
34.1
SSCNET receive data error
SD
(Note 5)
34.2
SSCNET connector connection error
SD
34.3
SSCNET communication data error
SD
34.4
Hardware error signal detection
SD
34.5
SSCNET receive data error (safety
observation function)
SD
34.6
SSCNET communication data error
(safety observation function)
SD
35
Command frequency
error
35.1
Command frequency error
SD
36
SSCNET receive error 2
36.1
Continuous communication data error
SD
36.2
Continuous communication data error
(safety observation function)
SD
37
Parameter error
37.1
Parameter setting range error
DB
37.2
Parameter combination error
DB
37.3
Point table setting error
DB
37.4
Command electronic gear setting error
2
DB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish